Check the health of my SSD

6,342

The 231 SSD_Life_Left value is 100 with fail threshold of 10.

Same is with 230 Life_Curve_Status. The value is 100.

Actually these parameters look perfect.

Share:
6,342

Related videos on Youtube

user72708
Author by

user72708

Updated on September 18, 2022

Comments

  • user72708
    user72708 over 1 year

    I want to check the status of my ssd under Ubuntu 14.04 so I use these commands:

    smartctl -a /dev/sda | grep Media_Wearout_Indicator
    sudo smartctl -a /dev/sda
    

    and this is the output:

    smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-57-generic] (local build)
    Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
    
    === START OF INFORMATION SECTION ===
    Model Family:     SandForce Driven SSDs
    Device Model:     KINGSTON SV300S37A120G
    Serial Number:    50026B774200F2E6
    LU WWN Device Id: 5 0026b7 74200f2e6
    Firmware Version: 521ABBF0
    User Capacity:    120.034.123.776 bytes [120 GB]
    Sector Size:      512 bytes logical/physical
    Rotation Rate:    Solid State Device
    Device is:        In smartctl database [for details use: -P show]
    ATA Version is:   ATA8-ACS, ACS-2 T13/2015-D revision 3
    SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
    Local Time is:    Mon Aug  3 16:03:14 2015 CEST
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled
    
    === START OF READ SMART DATA SECTION ===
    SMART overall-health self-assessment test result: PASSED
    
    General SMART Values:
    Offline data collection status:  (0x00) Offline data collection activity
                        was never started.
                        Auto Offline Data Collection: Disabled.
    Self-test execution status:      (   1) The previous self-test routine completed
                        without error or no self-test has ever 
                        been run.
    Total time to complete Offline 
    data collection:        (    0) seconds.
    Offline data collection
    capabilities:            (0x79) SMART execute Offline immediate.
                        No Auto Offline data collection support.
                        Suspend Offline collection upon new
                        command.
                        Offline surface scan supported.
                        Self-test supported.
                        Conveyance Self-test supported.
                        Selective Self-test supported.
    SMART capabilities:            (0x0003) Saves SMART data before entering
                        power-saving mode.
                        Supports SMART auto save timer.
    Error logging capability:        (0x01) Error logging supported.
                        General Purpose Logging supported.
    Short self-test routine 
    recommended polling time:    (   1) minutes.
    Extended self-test routine
    recommended polling time:    (  36) minutes.
    Conveyance self-test routine
    recommended polling time:    (   2) minutes.
    SCT capabilities:          (0x0025) SCT Status supported.
                        SCT Data Table supported.
    
    SMART Attributes Data Structure revision number: 10
    Vendor Specific SMART Attributes with Thresholds:
    ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
      1 Raw_Read_Error_Rate     0x0033   095   095   050    Pre-fail  Always       -       0/2484744
      5 Retired_Block_Count     0x0033   100   100   003    Pre-fail  Always       -       0
      9 Power_On_Hours_and_Msec 0x0032   099   099   000    Old_age   Always       -       1149h+09m+10.840s
     12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       469
    171 Program_Fail_Count      0x000a   000   000   000    Old_age   Always       -       0
    172 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always       -       0
    174 Unexpect_Power_Loss_Ct  0x0030   000   000   000    Old_age   Offline      -       27
    177 Wear_Range_Delta        0x0000   000   000   000    Old_age   Offline      -       1
    181 Program_Fail_Count      0x000a   000   000   000    Old_age   Always       -       0
    182 Erase_Fail_Count        0x0032   000   000   000    Old_age   Always       -       0
    187 Reported_Uncorrect      0x0012   100   100   000    Old_age   Always       -       0
    189 Airflow_Temperature_Cel 0x0000   041   046   000    Old_age   Offline      -       41 (Min/Max 14/46)
    194 Temperature_Celsius     0x0022   041   046   000    Old_age   Always       -       41 (Min/Max 14/46)
    195 ECC_Uncorr_Error_Count  0x001c   120   120   000    Old_age   Offline      -       0/2484744
    196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always       -       0
    201 Unc_Soft_Read_Err_Rate  0x001c   120   120   000    Old_age   Offline      -       0/2484744
    204 Soft_ECC_Correct_Rate   0x001c   120   120   000    Old_age   Offline      -       0/2484744
    230 Life_Curve_Status       0x0013   100   100   000    Pre-fail  Always       -       100
    231 SSD_Life_Left           0x0013   100   100   010    Pre-fail  Always       -       0
    233 SandForce_Internal      0x0032   000   000   000    Old_age   Always       -       1054
    234 SandForce_Internal      0x0032   000   000   000    Old_age   Always       -       1463
    241 Lifetime_Writes_GiB     0x0032   000   000   000    Old_age   Always       -       1463
    242 Lifetime_Reads_GiB      0x0032   000   000   000    Old_age   Always       -       2663
    
    SMART Error Log not supported
    
    SMART Self-test Log not supported
    
    SMART Selective self-test log data structure revision number 1
     SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
        1        0        0  Not_testing
        2        0        0  Not_testing
        3        0        0  Not_testing
        4        0        0  Not_testing
        5        0        0  Not_testing
    Selective self-test flags (0x0):
      After scanning selected spans, do NOT read-scan remainder of disk.
    If Selective self-test is pending on power-up, resume after 0 minute delay.
    

    I think that I have to change the ssd or make a backup, right?
    The values 230 Life_Curve_Status and 231 SSD_Life_Left seem very bad, am I wrong?

  • user72708
    user72708 almost 9 years
    yes, but the worst value for these fields is 100 (column WORST). The perfect value would be 1, am I wrong?
  • Pilot6
    Pilot6 almost 9 years
    "Worst" means "seen worst with this drive". So it always has been 100. It is perfect.