Dell PowerEdge 1950 physical disk has foreign status error
8,794
Ctrl-R during bootup brings up the BIOS menu for the controller. Go across to Foreign (Ctrl-n), hit F2 for options and choose Import Foreign Config to load previous config from the disks or choose clear foreign config to wipe it and start from scratch.
Author by
rezizter
Updated on September 18, 2022Comments
-
rezizter over 1 year
Dell PowerEdge 1950 has an issue with a raid. I have 2 disks on the raid, and it fails. When looking at Dell Open Manage it is because both disks show as state = foreign.
Name State Bus Protocol Media Revision Capacity Physical Disk 0:0:2 Foreign Execute SATA HDD AX001U 931.00GB Physical Disk 0:0:3 Foreign Execute SATA HDD AX001U 931.00GB
Under the "Available tasks" I can only blink and unblink the drives.How can I clear these errors and get the drives back online.
It is a dev machine so I don't mind rebuilding the machine.
-
rezizter over 10 yearsThank you. I have installed 2 Toshiba drives (not supported by Dell) Will clearing the foreign config mean that I wont get the error after rebooting?
-
JamesRyan over 10 yearsThis status refers to RAID config, not whether the drive is supported. On the perc 5/6, which go with this server, should not be restricted to Dell supported drives (although a standard firmware may be suboptimal), they will just give a warning in the event log.