dell poweredge pcie training error, what to do?

92,474

Solution 1

We managed to get it booted by turning it off, opening it up and checking the riser/pci, etc. card connections and re-seating them.

We had also tried several power downs, restarts, and removing the newer drive.

Solution 2

Having the same “PCle training error: Internal Storage Slot”. I replaced one of the two capacitors on the PCIe RAID controller that was showing signs of breakdown (expanded housing). 1500uf @ 6.3V. The system now boots and has been running for more than 24 horus.

Solution 3

dell poweredge servers are configured with only PCIe Gen 3. if your card is Gen2 or Gen1, then you will face training error.

check with your PCIe configuration. If it is FPGA Configured PCIe then check the configurations and bit file which should be strictly Gen3 only.

we too faced that issue and finally my friend find it.

Share:
92,474

Related videos on Youtube

Scott Szretter
Author by

Scott Szretter

As. Director or Information Technology / Developer N1VAN www.508tech.com Apache / PHP / MySQL IIS / ASP.NET / MS-SQL Flex / Flash Builder / Actionscript .NET / C# / VB / MVC JavaScript / XML / HTML / DHTML Java / Objective-C Enterprise Networking / Server & Workstation Hardware / Storage VMWARE / VEEAM

Updated on September 18, 2022

Comments

  • Scott Szretter
    Scott Szretter almost 2 years

    After telling the server to reboot, it is now displaying an “PCle training error: Internal Storage Slot” Then the next line was “System Halted!”. It will not boot.

    Recently a failed scsi hot swap drive was replaced, but it rebuilt fine and has been running fine for a week.

    Any ideas?

  • Nils
    Nils almost 13 years
    Any reason why you did not call Dell?
  • Nils
    Nils almost 13 years
    That`s a reason, indeed. Perhaps you could mention that next time.
  • Matt
    Matt almost 12 years
    I would add to this that Dell had me TOTALLY take the RAID card out of the box, restart it without the card, shut down again, and put the RAID card back in. This apparently /really/ reseats the card as opposed to just pushing down on it to make sure it's "in". It worked for me on a Dell R420.
  • Kreker
    Kreker over 5 years
    Having the same problem and after opening the server I saw the 2 capacitors were very "expanded". I will try to replace them