Finding out why Dell Controller is Degraded
Solution 1
The controller state requires that both the Controller Firmware and the kernel module (driver) be up to date. Once I updated both of those the controller state changed to "Ready."
Solution 2
How old is your server? In the dell docs, the degraded state of the controller means that the battery should be reconditioned. Normally this is done automatically, but if too old then you need to change it.
PS: if you have openmanage installed, there's somewhere a option to manually recondition the battery. Be careful because that task takes about 8-10 hours and in that time the battery is discharged and recharged.
Related videos on Youtube
Kyle Brandt
Updated on September 17, 2022Comments
-
Kyle Brandt over 1 year
I installed open manage on a couple of my PE 2950s for snmp monitoring of the RAID. All the checks seem to come back okay except for controllerState:
[root@aMachine ~]# snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m +StorageManagement-MIB controllerstate StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6)
Other checks seems to indicate the battery, LD, and physicals disks are all good unless I missing something. Can anyone tell if I am missing something or neglecting something import in my RAID monitoring/understanding? I get degraded for both these servers I have set up.
A walk of the entire storage management tree for on of them:
StorageManagement-MIB::softwareVersion.0 = STRING: "3.2.0" StorageManagement-MIB::globalStatus.0 = INTEGER: warning(2) StorageManagement-MIB::softwareManufacturer.0 = STRING: "Dell Inc." StorageManagement-MIB::softwareProduct.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::softwareDescription.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::displayName.0 = STRING: "Server Administrator (Storage Management)" StorageManagement-MIB::description.0 = STRING: "Configuration and monitoring of disk storage devices." StorageManagement-MIB::agentVendor.0 = STRING: "Dell Inc." StorageManagement-MIB::agentTimeStamp.0 = INTEGER: 1273842310 StorageManagement-MIB::agentGetTimeout.0 = INTEGER: 5 StorageManagement-MIB::agentModifiers.0 = INTEGER: 0 StorageManagement-MIB::agentRefreshRate.0 = INTEGER: 300 StorageManagement-MIB::agentMibVersion.0 = STRING: "3.2" StorageManagement-MIB::agentManagementSoftwareURLName.0 = "" StorageManagement-MIB::agentGlobalSystemStatus.0 = INTEGER: nonCritical(4) StorageManagement-MIB::agentLastGlobalSystemStatus.0 = INTEGER: ok(3) StorageManagement-MIB::agentSmartThermalShutdown.0 = INTEGER: notApplicable(3) StorageManagement-MIB::controllerNumber.1 = INTEGER: 1 StorageManagement-MIB::controllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::controllerVendor.1 = STRING: "DELL" StorageManagement-MIB::controllerType.1 = INTEGER: sas(6) StorageManagement-MIB::controllerState.1 = INTEGER: degraded(6) StorageManagement-MIB::controllerRebuildRateInPercent.1 = INTEGER: 30 StorageManagement-MIB::controllerFWVersion.1 = STRING: "5.0.2-0003" StorageManagement-MIB::controllerCacheSizeInMB.1 = INTEGER: 256 StorageManagement-MIB::controllerCacheSizeInBytes.1 = INTEGER: 0 StorageManagement-MIB::controllerPhysicalDeviceCount.1 = INTEGER: 5 StorageManagement-MIB::controllerLogicalDeviceCount.1 = INTEGER: 1 StorageManagement-MIB::controllerRollUpStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerComponentStatus.1 = INTEGER: nonCritical(4) StorageManagement-MIB::controllerNexusID.1 = STRING: "\\0" StorageManagement-MIB::controllerAlarmState.1 = INTEGER: disabled(2) StorageManagement-MIB::controllerDriverVersion.1 = STRING: "00.00.03.05 " StorageManagement-MIB::controllerPCISlot.1 = STRING: "embedded" StorageManagement-MIB::controllerClusterMode.1 = INTEGER: notApplicable(99) StorageManagement-MIB::controllerMinFWVersion.1 = STRING: "5.2.1-0067" StorageManagement-MIB::controllerMinDriverVersion.1 = STRING: "00.00.03.21" StorageManagement-MIB::controllerChannelCount.1 = INTEGER: 2 StorageManagement-MIB::controllerReconstructRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadRate.1 = INTEGER: 30 StorageManagement-MIB::controllerBGIRate.1 = INTEGER: 30 StorageManagement-MIB::controllerCheckConsistencyRate.1 = INTEGER: 30 StorageManagement-MIB::controllerPatrolReadMode.1 = INTEGER: automatic(1) StorageManagement-MIB::controllerPatrolReadState.1 = INTEGER: stopped(1) StorageManagement-MIB::controllerPatrolReadIterations.1 = INTEGER: 162 StorageManagement-MIB::controllerEntry.57.1 = INTEGER: 99 StorageManagement-MIB::controllerEntry.58.1 = INTEGER: 99 StorageManagement-MIB::channelNumber.1 = INTEGER: 1 StorageManagement-MIB::channelNumber.2 = INTEGER: 2 StorageManagement-MIB::channelName.1 = STRING: "Connector 0" StorageManagement-MIB::channelName.2 = STRING: "Connector 1" StorageManagement-MIB::channelState.1 = INTEGER: ready(1) StorageManagement-MIB::channelState.2 = INTEGER: ready(1) StorageManagement-MIB::channelRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::channelComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::channelNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::channelNexusID.2 = STRING: "\\0\\1" StorageManagement-MIB::channelBusType.1 = INTEGER: sas(8) StorageManagement-MIB::channelBusType.2 = INTEGER: sas(8) StorageManagement-MIB::enclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::enclosureName.1 = STRING: "Backplane" StorageManagement-MIB::enclosureVendor.1 = STRING: "DELL" StorageManagement-MIB::enclosureState.1 = INTEGER: ready(1) StorageManagement-MIB::enclosureProductID.1 = STRING: "BACKPLANE " StorageManagement-MIB::enclosureType.1 = INTEGER: internal(1) StorageManagement-MIB::enclosureChannelNumber.1 = INTEGER: 0 StorageManagement-MIB::enclosureRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::enclosureNexusID.1 = STRING: "\\0\\0\\0" StorageManagement-MIB::enclosureFirmwareVersion.1 = STRING: "1.00" StorageManagement-MIB::enclosureSASAddress.1 = STRING: "50019090B4C67200" StorageManagement-MIB::arrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskVendor.1 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.2 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.3 = STRING: "DELL " StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL " StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3) StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3) StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS " StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 " StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS " StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V " StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 " StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106" StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106" StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0" StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0" StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2 StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3 StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8) StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5) StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3) StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0" StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1" StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2" StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3" StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 " StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 " StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 " StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 " StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201" StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89" StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9" StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1" StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1) StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1) StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07" StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005" StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005" StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2) StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0 StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane" StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1 StorageManagement-MIB::batteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryVendor.1 = STRING: "DELL" StorageManagement-MIB::batteryState.1 = INTEGER: ready(1) StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2) StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21 StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16) StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0 StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168 StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0" StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1 StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated" StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda" StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1) StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784 StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3) StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5) StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99) StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10) StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536 StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0 StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3) StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0" StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1) StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2 StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3" StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3 StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0" StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1 StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1
Update in Response To Battery Question:
Not entirely sure about the age, a few years? Maybe this helps:[root@aMachine ~]# /opt/MegaRAID/MegaCli/MegaCli -AdpBbuCmd -aALL BBU status for Adapter: 0 BatteryType: BBU Voltage: 4054 mV Current: 0 mA Temperature: 10 C Firmware Status: 00000000 Battery state: GasGuageStatus: Fully Discharged : No Fully Charged : Yes Discharging : Yes Initialized : Yes Remaining Time Alarm : No Remaining Capacity Alarm: No Discharge Terminated : No Over Temperature : No Charging Terminated : No Over Charged : No Relative State of Charge: 100 % Charger Status: Complete Remaining Capacity: 1472 mAh Full Charge Capacity: 1478 mAh isSOHGood: Yes BBU Capacity Info for Adapter: 0 Relative State of Charge: 100 % Absolute State of charge: 77 % Remaining Capacity: 1472 mAh Full Charge Capacity: 1478 mAh Run time to empty: 65535 Min Average time to empty: 65535 Min Average Time to full: 65535 Min Cycle Count: 15 Max Error: 2 % Remaining Capacity Alarm: 190 mAh Remaining Time Alarm: 10 Min BBU Design Info for Adapter: 0 Date of Manufacture: 01/09, 2007 Design Capacity: 1900 mAh Design Voltage: 3700 mV Specification Info: 8000 Serial Number: 2991 Pack Stat Configuration: 0xe49c Manufacture Name: SMP-PA Device Name: X848371 Device Chemistry: LION BBU Properties for Adapter: 0 Auto Learn Period: 7776000 Sec Next Learn time: 327149518 Sec Learn Delay Interval:0 Hours Auto-Learn Mode: Enabled
Update 2, this is just to go for a question length record:
Hmm.. One of the two it turns out that the battery is about to start this process on its own. However, this doesn't seem to be the case on the other one. So I am thinking it is something else?/opt/MegaRAID/MegaCli/MegaCli -FwTermLog -Dsply -aALL ... 05/08/10 3:40:18: Next PR scheduled to start at 05/15/10 3:00:00 05/10/10 10:52:14: EVT#08474-05/10/10 10:52:14: 157=Battery relearn will start in 4 days 05/12/10 10:52:49: EVT#08475-05/12/10 10:52:49: 158=Battery relearn will start in 2 day 05/13/10 10:52:34: EVT#08476-05/13/10 10:52:34: 159=Battery relearn will start in 1 day 05/13/10 15:43:08: EVT#08477-05/13/10 15:43:08: 73=VD 00/0 Properties updated to [ID=00,dcp=01,ccp=01,ap=0,dc=0,dbgi=0] (from [ID=00,dcp=01,ccp=01,ap=0,dc=0,dbgi=0]) 05/13/10 13:30:22: EVT#08478-05/13/10 13:30:22: 44=Time established as 05/13/10 13:30:22; (5228737 seconds since power on) 05/13/10 13:30:24: EVT#08479-05/13/10 13:30:24: 30=Event log cleared 05/13/10 13:30:54: EVT#08480-05/13/10 13:30:54: 30=Event log cleared 05/13/10 13:31:12: EVT#08481-05/13/10 13:31:12: 30=Event log cleared 05/13/10 13:31:31: EVT#08482-05/13/10 13:31:31: 30=Event log cleared 05/14/10 5:52:43: EVT#08483-05/14/10 5:52:43: 160=Battery relearn will start in 5 hours
-
Kyle Brandt almost 14 yearsI should also mention that
/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL
reuturns optimal on both servers.
-
-
PiL almost 14 yearsLooking at that report it doesn't look bad. The year should be 2007 so, yes, about 3 years. Anyway the reconditioning should be available only for NiMHi batteries and your is LION. As dyasny suggested, try to replace the battery with another one, if you have another one.
-
David Corsalini almost 14 yearsIn my experience, calling support is faster, and if you want the solution to be known, blog about it (that's what I usually do) From my own experience in Dell support, there was a bunch of BBU's shipped that spent a bit too long in storage, and would fail very quickly. Once a call about those came in, the tech usually dispatched a replacement battery right away, no extra troubleshooting. Maybe you've got one of those, but only the support guys would be able to say for sure
-
Mike S over 7 years-1 to dynasy's comment because years down the road, working with older out-of-support hardware, q & a like this is very helpful. +1 to Kyle Brandt because he's right on the money. Here it is, 6 years later, and a Google search led me right to this webpage. His reasoning is not only sound, it saves a lot of time (support calls in my experience sometimes take an hour to get to the same conclusion I can reach in 10 minutes online).
-
David Corsalini over 7 years@MikeS PE2950 came out in 2007, which makes it 9 years old today. My answer was provided in 2010, while it was still not EOL. If you go through serverfault and -1 all the answers that lost their relevance in the timespan of 6 years, you'll have a full time job for a very long time. Oh, and BTW, as someone who used to work at Dell server support, even if you call in about EOL hardware, they will try to help with troubleshooting, even if they will not replace parts for you, so calling them may still be useful even for a 9 year old machine.
-
Mike S over 7 years@dyasny -1 for missing my whole point, which is: People are more than welcome to post their questions here, even for supported hardware/software, because there are very good reasons to do so- as evidenced by my good forture to come upon this question years later that has relevance to me. Stating your timeline misses my point entirely. Furthermore, I've often found the support and answers here are often better than the vendors, because your support call may be answered by a college freshout reading from a troubleshooting guide. Here, you bump into IT guys with 20 years' experience.
-
David Corsalini over 7 years@MikeS You miss the whole point of this site, and I do not appreciate the condescending tone either. You have just bumped into an "IT guy with 20 years' experience" right here, and he tells you the advice to talk to a vendor for brandname hardware is valid and works. Downvoting is for wrong and misleading answers, not for what you consider a worse solution than others. Besides, a collee grad working at Dell has a quality lead who has those same 20 years of experience, plus a lot of internal tools and information available to him.
-
Mike S over 7 yearsYou're right, I should not have downvoted. Although I don't like your advice, I was wrong to downvote. I appreciate the education.