Force RAID 1+0 HP Smart Array to rebuild
You can't.
"Ready for Rebuild" status means that the rebuild is likely running into a read error from a partner disk. You may have another failing disk in the array. See: Force LUN in a HP Smart Array to rebuild
- Did you recently replace a disk?
- Please provide the firmware revision of the Smart Array E200i controller you're using.
- Please show
ctrl all show config detail
I'd check your backups and schedule time to power the system off and back on again. This could be a firmware issue, depending on what happened before this, or you may have the failing disk situation described above.
Related videos on Youtube
Tiago Cruz
Updated on September 18, 2022Comments
-
Tiago Cruz over 1 year
I have a RAID10 with status "Ready for Rebuild", but how can I force the rebuild?
# hpacucli ctrl all show config Smart Array E200 in Slot 0 (Embedded) (sn: PA6C90N9SW82IU) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (68.3 GB, RAID 1, OK) physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (2.0 TB, RAID 1+0, Ready for Rebuild) <--- physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK)
Details about the RAID1+0:
# hpacucli controller slot=0 logicaldrive 2 show Smart Array E200 in Slot 0 (Embedded) array B Logical Drive: 2 Size: 2.0 TB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 128 KB Full Stripe Size: 384 KB Status: Ready for Rebuild <---- Caching: Enabled Unique Identifier: 600508B100104E395357383249550009 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A00E9989PA6C90N9SW82IU44B0 Mirror Group 0: physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK) Mirror Group 1: physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK) Drive Type: Data
This is the controller:
RAID bus controller: Hewlett-Packard Company Smart Array E200i (SAS Controller)
Thanks a lot!
-- edit
As requested, follow the 'crtl all show config' using Firmware Version: 1.78:
# hpacucli ctrl all show config detail Smart Array E200 in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: PA6C90N9SW82IU Cache Serial Number: P9A3A0B9SW8426 RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: A Firmware Version: 1.78 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Post Prompt Timeout: 0 secs Cache Board Present: True Cache Status: OK Cache Ratio: 50% Read / 50% Write Drive Write Cache: Disabled Total Cache Size: 128 MB Total Cache Memory Available: 96 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: False
Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data
Logical Drive: 1 Size: 68.3 GB Fault Tolerance: RAID 1 Heads: 255 Sectors Per Track: 32 Cylinders: 17562 Strip Size: 128 KB Full Stripe Size: 128 KB Status: OK Caching: Enabled Unique Identifier: 600508B100104E395357383249550006 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 99 MB OS Status: LOCKED Logical Drive Label: A0081154PA6C90N9SW82IUBFAF Mirror Group 0: physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK) Mirror Group 1: physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK) Drive Type: Data physicaldrive 2I:1:1 Port: 2I Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD0 Serial Number: BJL4P86004VM0826 Model: HP DF072BAFDT PHY Count: 2 PHY Transfer Rate: 3.0Gbps, Unknown physicaldrive 2I:1:2 Port: 2I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 15000 Firmware Revision: HPD0 Serial Number: BJL4P86004RY0826 Model: HP DF072BAFDT PHY Count: 2 PHY Transfer Rate: 3.0Gbps, Unknown
Array: B Interface Type: SATA Unused Space: 0 MB Status: OK Array Type: Data
Logical Drive: 2 Size: 2.0 TB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 128 KB Full Stripe Size: 384 KB Status: Ready for Rebuild Caching: Enabled Unique Identifier: 600508B100104E395357383249550009 Disk Name: /dev/cciss/c0d1 Mount Points: None OS Status: LOCKED Logical Drive Label: A00E9989PA6C90N9SW82IU44B0 Mirror Group 0: physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK) Mirror Group 1: physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK) physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK) physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK) Drive Type: Data physicaldrive 1I:1:5 Port: 1I Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPG1 Serial Number: 9QK117ZV Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 1I:1:6 Port: 1I Box: 1 Bay: 6 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPG1 Serial Number: 9QK10N2K Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 1I:1:7 Port: 1I Box: 1 Bay: 7 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPGB Serial Number: 9QK0X1DQ Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 1I:1:8 Port: 1I Box: 1 Bay: 8 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPGB Serial Number: 9QK2QK4H Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 2I:1:3 Port: 2I Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPG1 Serial Number: 9QK119T8 Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 2I:1:4 Port: 2I Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 750 GB Firmware Revision: HPG1 Serial Number: 9QK10NMD Model: ATA GB0750C8047 SATA NCQ Capable: False PHY Count: 1 PHY Transfer Rate: 1.5Gbps
-
Tiago Cruz over 9 yearsThanks for the answer! - Yes, we changed a failed disk - Firmware 1.78 - I edit the original message with 'show config detail' - We let the machine power off for a while, and then turn on again, but with the same error :(
-
ewwhite over 9 yearsTry updating the controller firmware. The current version is: 1.86
-
Tiago Cruz over 9 yearsAfter the firmware upgrade and reboot, the recovery begins: logicaldrive 2 (2.0 TB, RAID 1+0, Recovering, 1% complete) Let's see if they will finish :)
-
Tiago Cruz over 9 yearsUsing Firmware Version: 1.86, after the reboot, the status is "Ready for Rebuild" again :(
-
ewwhite over 9 years@TiagoCruz Then you likely have a failed or failing disk in the array with read errors. There's also a slight chance that you need a disk firmware update. But at this point, you may not have options.