Force RAID 1+0 HP Smart Array to rebuild

9,026

You can't.

"Ready for Rebuild" status means that the rebuild is likely running into a read error from a partner disk. You may have another failing disk in the array. See: Force LUN in a HP Smart Array to rebuild

  • Did you recently replace a disk?
  • Please provide the firmware revision of the Smart Array E200i controller you're using.
  • Please show ctrl all show config detail

I'd check your backups and schedule time to power the system off and back on again. This could be a firmware issue, depending on what happened before this, or you may have the failing disk situation described above.

Share:
9,026

Related videos on Youtube

Tiago Cruz
Author by

Tiago Cruz

Updated on September 18, 2022

Comments

  • Tiago Cruz
    Tiago Cruz over 1 year

    I have a RAID10 with status "Ready for Rebuild", but how can I force the rebuild?

    # hpacucli ctrl all show config 
    
    Smart Array E200 in Slot 0 (Embedded)     (sn: PA6C90N9SW82IU)
    
    array A (SAS, Unused Space: 0  MB)
    
      logicaldrive 1 (68.3 GB, RAID 1, OK)
    
      physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK)
      physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK)
    
    array B (SATA, Unused Space: 0  MB)
    
      logicaldrive 2 (2.0 TB, RAID 1+0, Ready for Rebuild) <---
    
      physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK)
      physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK)
      physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK)
      physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK)
      physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK)
      physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK)
    

    Details about the RAID1+0:

    # hpacucli controller slot=0 logicaldrive 2 show 
    
    Smart Array E200 in Slot 0 (Embedded)
    
    array B
    
      Logical Drive: 2
         Size: 2.0 TB
         Fault Tolerance: RAID 1+0
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Strip Size: 128 KB
         Full Stripe Size: 384 KB
         Status: Ready for Rebuild  <----
         Caching:  Enabled
         Unique Identifier: 600508B100104E395357383249550009
         Disk Name: /dev/cciss/c0d1
         Mount Points: None
         OS Status: LOCKED
         Logical Drive Label: A00E9989PA6C90N9SW82IU44B0
         Mirror Group 0:
            physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK)
            physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK)
            physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK)
         Mirror Group 1:
            physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK)
            physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK)
            physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK)
         Drive Type: Data
    

    This is the controller:

    RAID bus controller: Hewlett-Packard Company Smart Array E200i (SAS Controller)
    

    Thanks a lot!

    -- edit

    As requested, follow the 'crtl all show config' using Firmware Version: 1.78:

    # hpacucli ctrl all show config detail
    
    Smart Array E200 in Slot 0 (Embedded)
    Bus Interface: PCI
    Slot: 0
    Serial Number: PA6C90N9SW82IU
    Cache Serial Number: P9A3A0B9SW8426
    RAID 6 (ADG) Status: Disabled
    Controller Status: OK
    Hardware Revision: A
    Firmware Version: 1.78
    Rebuild Priority: Medium
    Expand Priority: Medium
    Surface Scan Delay: 15 secs
    Surface Scan Mode: Idle
    Post Prompt Timeout: 0 secs
    Cache Board Present: True
    Cache Status: OK
    Cache Ratio: 50% Read / 50% Write
    Drive Write Cache: Disabled
    Total Cache Size: 128 MB
    Total Cache Memory Available: 96 MB
    No-Battery Write Cache: Disabled
    Cache Backup Power Source: Batteries
    Battery/Capacitor Count: 1
    Battery/Capacitor Status: OK
    SATA NCQ Supported: False
    

    Array: A Interface Type: SAS Unused Space: 0 MB Status: OK Array Type: Data

      Logical Drive: 1
         Size: 68.3 GB
         Fault Tolerance: RAID 1
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 17562
         Strip Size: 128 KB
         Full Stripe Size: 128 KB
         Status: OK
         Caching:  Enabled
         Unique Identifier: 600508B100104E395357383249550006
         Disk Name: /dev/cciss/c0d0
         Mount Points: /boot 99 MB
         OS Status: LOCKED
         Logical Drive Label: A0081154PA6C90N9SW82IUBFAF
         Mirror Group 0:
            physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK)
         Mirror Group 1:
            physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK)
         Drive Type: Data
    
      physicaldrive 2I:1:1
         Port: 2I
         Box: 1
         Bay: 1
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 72 GB
         Rotational Speed: 15000
         Firmware Revision: HPD0
         Serial Number: BJL4P86004VM0826
         Model: HP      DF072BAFDT      
         PHY Count: 2
         PHY Transfer Rate: 3.0Gbps, Unknown
    
      physicaldrive 2I:1:2
         Port: 2I
         Box: 1
         Bay: 2
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 72 GB
         Rotational Speed: 15000
         Firmware Revision: HPD0
         Serial Number: BJL4P86004RY0826
         Model: HP      DF072BAFDT      
         PHY Count: 2
         PHY Transfer Rate: 3.0Gbps, Unknown
    

    Array: B Interface Type: SATA Unused Space: 0 MB Status: OK Array Type: Data

      Logical Drive: 2
         Size: 2.0 TB
         Fault Tolerance: RAID 1+0
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Strip Size: 128 KB
         Full Stripe Size: 384 KB
         Status: Ready for Rebuild
         Caching:  Enabled
         Unique Identifier: 600508B100104E395357383249550009
         Disk Name: /dev/cciss/c0d1
         Mount Points: None
         OS Status: LOCKED
         Logical Drive Label: A00E9989PA6C90N9SW82IU44B0
         Mirror Group 0:
            physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 750 GB, OK)
            physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 750 GB, OK)
            physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 750 GB, OK)
         Mirror Group 1:
            physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 750 GB, OK)
            physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK)
            physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SATA, 750 GB, OK)
         Drive Type: Data
    
      physicaldrive 1I:1:5
         Port: 1I
         Box: 1
         Bay: 5
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPG1    
         Serial Number: 9QK117ZV            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
      physicaldrive 1I:1:6
         Port: 1I
         Box: 1
         Bay: 6
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPG1    
         Serial Number: 9QK10N2K            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
      physicaldrive 1I:1:7
         Port: 1I
         Box: 1
         Bay: 7
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPGB    
         Serial Number: 9QK0X1DQ            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
      physicaldrive 1I:1:8
         Port: 1I
         Box: 1
         Bay: 8
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPGB    
         Serial Number: 9QK2QK4H            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
      physicaldrive 2I:1:3
         Port: 2I
         Box: 1
         Bay: 3
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPG1    
         Serial Number: 9QK119T8            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
      physicaldrive 2I:1:4
         Port: 2I
         Box: 1
         Bay: 4
         Status: OK
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 750 GB
         Firmware Revision: HPG1    
         Serial Number: 9QK10NMD            
         Model: ATA     GB0750C8047     
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps
    
  • Tiago Cruz
    Tiago Cruz over 9 years
    Thanks for the answer! - Yes, we changed a failed disk - Firmware 1.78 - I edit the original message with 'show config detail' - We let the machine power off for a while, and then turn on again, but with the same error :(
  • ewwhite
    ewwhite over 9 years
    Try updating the controller firmware. The current version is: 1.86
  • Tiago Cruz
    Tiago Cruz over 9 years
    After the firmware upgrade and reboot, the recovery begins: logicaldrive 2 (2.0 TB, RAID 1+0, Recovering, 1% complete) Let's see if they will finish :)
  • Tiago Cruz
    Tiago Cruz over 9 years
    Using Firmware Version: 1.86, after the reboot, the status is "Ready for Rebuild" again :(
  • ewwhite
    ewwhite over 9 years
    @TiagoCruz Then you likely have a failed or failing disk in the array with read errors. There's also a slight chance that you need a disk firmware update. But at this point, you may not have options.