I had the same issue and found an answer. The variable slave_sql_verify_checksum as to be set in the configuration file my.cnf. Set slave_sql_verify_checksum = NONE and restart the server.

Share:
10,685

Related videos on Youtube

Mustermann
Author by

Mustermann

Updated on June 04, 2022

Comments

  • Mustermann
    Mustermann almost 2 years

    I am currently trying to get a MariaDB 10.2.9 to run as a slave of a mysql 5.5 master but i keep getting the same error (Last_IO_Errno: 1595, Relay log write failure: could not queue event from master)

    As there is some difference in version between master and slave i had to set

    set global binlog_checksum='NONE';
    

    All in all i took a mysqldump of the master, read the log_pos/file and

    SET GLOBAL server_id=2;
    CHANGE MASTER TO 
    MASTER_HOST='10.145.46.11',MASTER_USER='replicant',MASTER_PASSWORD='...', 
    MASTER_LOG_FILE='mysql-bin.000042', MASTER_LOG_POS=107;
    start slave;
    

    But the IO Thread simply wont start, the mariadb.log says:

    ...
    2017-10-31 11:44:41 140026338711296 [Note] Slave SQL thread initialized, starting replication in log 'mysql-bin.000007' at position 107, relay log './mariadb-relay-bin.000001' position: 4
    2017-10-31 11:44:41 140027007977216 [Note] Slave I/O thread: connected to master '[email protected]:3306',replication started in log 'mysql-bin.000007' at position 107
    2017-10-31 11:44:42 140027007977216 [Warning] Slave I/O: Notifying master by SET @master_binlog_checksum= @@global.binlog_checksum failed with error: Unknown system variable 'binlog_checksum', Internal MariaDB error code: 1193
    2017-10-31 11:44:42 140027007977216 [ERROR] Slave I/O: Replication event checksum verification failed while reading from network, Internal MariaDB error code: 1743
    2017-10-31 11:44:42 140027007977216 [ERROR] Slave I/O: Relay log write failure: could not queue event from master, Internal MariaDB error code: 1595
    2017-10-31 11:44:42 140027007977216 [Note] Slave I/O thread exiting, read up to log 'mysql-bin.000007', position 107
    ....
    

    I am also not sure what kind of checksum is failing here (mysql reference says "replication event checksum"?), ive tried:

    set global slave_sql_verify_checksum=0;
    

    current status is:

    MariaDB [(none)]> show slave status \G;
    *************************** 1. row ***************************
                   Slave_IO_State: 
                      Master_Host: 10.145.46.11
                      Master_User: replicant
                      Master_Port: 3306
                    Connect_Retry: 60
                  Master_Log_File: mysql-bin.000007
              Read_Master_Log_Pos: 107
                   Relay_Log_File: mariadb-relay-bin.000001
                    Relay_Log_Pos: 4
            Relay_Master_Log_File: mysql-bin.000007
                 Slave_IO_Running: No
                Slave_SQL_Running: Yes
                  Replicate_Do_DB: 
              Replicate_Ignore_DB: 
               Replicate_Do_Table: 
           Replicate_Ignore_Table: 
          Replicate_Wild_Do_Table: 
      Replicate_Wild_Ignore_Table: 
                       Last_Errno: 0
                       Last_Error: 
                     Skip_Counter: 0
              Exec_Master_Log_Pos: 107
                  Relay_Log_Space: 256
                  Until_Condition: None
                   Until_Log_File: 
                    Until_Log_Pos: 0
               Master_SSL_Allowed: No
               Master_SSL_CA_File: 
               Master_SSL_CA_Path: 
                  Master_SSL_Cert: 
                Master_SSL_Cipher: 
                   Master_SSL_Key: 
            Seconds_Behind_Master: NULL
    Master_SSL_Verify_Server_Cert: No
                    Last_IO_Errno: 1595
                    Last_IO_Error: Relay log write failure: could not queue event from master
                   Last_SQL_Errno: 0
                   Last_SQL_Error: 
      Replicate_Ignore_Server_Ids: 
                 Master_Server_Id: 1
                   Master_SSL_Crl: 
               Master_SSL_Crlpath: 
                       Using_Gtid: No
                      Gtid_IO_Pos: 
          Replicate_Do_Domain_Ids: 
      Replicate_Ignore_Domain_Ids: 
                    Parallel_Mode: conservative
                        SQL_Delay: 0
              SQL_Remaining_Delay: NULL
          Slave_SQL_Running_State: Slave has read all relay log; waiting for the slave I/O thread to update it