Replace a failed disk in EMC CX2-30 san

5,350

Solution 1

From EMC Powerlink you can download the Unisphere Service Manager, install this on a management station with access to the array via https. It will have a wizard in it to guide you through the drive replacement after confirming it has moved over to hot spare/etc.

Again, if you have support on the array though, EMC will dispatch a technician to replace it for you.

Solution 2

Here is what I would do.. I would move one of the two hotspares over to the raid5 lun so it can begin to rebuild it.. once rebuilt just remove the disk and put in a replacement.

If still under warranty EMC will send a tech out to do it.

Share:
5,350

Related videos on Youtube

Nathan Friend
Author by

Nathan Friend

Web developer and Opensource advocate.

Updated on September 18, 2022

Comments

  • Nathan Friend
    Nathan Friend almost 2 years

    Where can I find the procedure for replacing a disk in an EMC CX2-30 san.

    Amber light showing on one disk, NaviSphere shows the disk status as "Requested Bypass"

    The affected LUN is in a RAID 5 configuration.

    There are two hot spares in the unowned LUN, one has status "Hot spare ready". The other has status "Enabled".