What is "Data Protection" option in WebBIOS 6.1-45-Rel of ServeRAID M5110e controller?
there is no official documentation from IBM about this feature but our local dealer referred to the documentation directly from Seagate:
EDIT (To avoid link rot): It states that the feature relies on the T10 Protection Information (T10-PI) standard which adds an extra eight bytes of information to the 512-byte sectors of hard drives, increasing sector size to 520 bytes. These extra eight bytes of metadata are used to verify the integrity of the 512 bytes of data in the sector. This should prevent data from silent corruption. Due to the extra overhead of transferring PI metadata from the media, sequential performance of a PI drive will be reduced by approximately 1.56%.
Related videos on Youtube
gapsf
Updated on September 18, 2022Comments
-
gapsf almost 2 years
What is "Data Protection"`option in WebBIOS 6.1-45-Rel during creation of new Drive Group?
Server is IBM x3650 M4 with ServeRAID M5110e controller.
User's Guide (here http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5086126) does not provide any details about it...-
fsr almost 9 yearsWARNING: take a look at this if you're considering enabling this option in a System x3650 M4 server. I had it enabled (no idea how, it's supposed to be off by default), and caused random controller errors (critical, fatal and catastrophic): www-947.ibm.com/support/entry/myportal/…
-
-
pauska over 10 yearsThis is the same protection feature that EMC/NetApp (and others) use in enterprise SAN's. Just for the record. :)
-
Zachw6 over 8 yearsLooks like Seagate has changed the name of the file for the Whitepaper. The following link works: seagate.com/files/staticfiles/docs/pdf/whitepaper/…