MegaCli64 -PDInfo shows drive but other commands says device does not exist
I got the same error today. On solution for me was to dump the events on the RAID Card:
megacli -AdpEventLog -GetEvents -f events -aAll
After reading the events, I found my problem:
Event Description: Inserted: PD 07(e0x20/s7)
Event Description: PD 07(e0x20/s7) is not a certified drive
My RAID Card, on my DELL server, is a H700 RAID Card. It only support specific DELL Disks.
I have read that a Firmware upgrade can remove this limitation, I will try. I hope you will have a better solution in your case...
Related videos on Youtube
user3221510
Updated on September 18, 2022Comments
-
user3221510 almost 2 years
A drive recently went missing on our IBM server. It has happened on other servers in the past and I usually just replace them with out a problem. On one it is not automatically adding the new drive.
I run the command:
MegaCli64 -PDInfo -PhysDrv [252:0] -a0
and I receive the drive information:
Enclosure Device ID: 252 Slot Number: 0 Enclosure position: N/A Device Id: 11 WWN: 5000C50055138398 Sequence Number: 17 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 0 KB [0x0 Sectors] Non Coerced Size: 0 KB [0x0 Sectors] Coerced Size: 0 KB [0x0 Sectors] Firmware state: Unconfigured(good), Spun Up Device Firmware Level: B559 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50055138399 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: IBM-ESXSST9300605SS B5596XP3S49F0215B559 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: Unknown Link Speed: Unknown Media Type: Hard Disk Device Drive Temperature : N/A PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: Unknown Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No
If I try to add the drive as a replacement/hot spare/ or any form of manipulation I receive the error.
sudo MegaCli64 -PdReplaceMissing -PhysDrv [?:0] -Array0 -Row1 -a0 Adapter: 0: Failed to replace Missing PD at Array 0, Row 1. FW error description: The requested command cannot be completed, as the specified device does not exist. Exit Code: 0x0c
How do I replace the missing disk in the raid?
-
Andrew Schulman over 10 yearsWhat is your question?
-
user3221510 over 10 yearsHow do I replace the missing disk in the raid?
-