Problems setting NTP sever with w32tm for a DC that is a Hyper-V guest

7,892

The problem seems to be with the way you specify the peers.

The documentation says :

When specifying multiple peers, use a space as the delimiter and enclose them in quotation marks.

Share:
7,892

Related videos on Youtube

Community
Author by

Community

Updated on September 17, 2022

Comments

  • Community
    Community over 1 year

    I have tried to sett my DC to get its time from several NTP severs. I follow this answer (W32Time sync problems for Hyper-V Guests (W32Time Event IDs 38, 24, 29, 35)) to do it.

    First I disable Time Synchronization in the Hyper-V Integration Services for each guest. Then restart the Windows Time serviceon the guest.

    I had before this used this command: w32tm /config /manualpeerlist:"ntp.uio.no;timekeeper. uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn cfromflags:manual /reliable:yes /update

    And the cmd sad: The command completed successfully.

    But the time was still 10 min wrong... I run w32tm again after restarted the DC without it having any effect. The w32tm /query /status still say: "Source: Local CMOS Clock"


    FROM MY CMD:

    Microsoft Windows [Version 6.0.6002]
    Copyright (c) 2006 Microsoft Corporation.  All rights reserved.
    
    C:\Users\Administrator.MHG>w32tm /query /status
    
    Leap Indicator: 0(no warning)
    
    Stratum: 1 (primary reference - syncd by radio clock)
    
    Precision: -6 (15.625ms per tick)
    
    Root Delay: 0.0000000s
    
    Root Dispersion: 10.0000000s
    
    ReferenceId: 0x4C4F434C (source name:  "LOCL")
    
    Last Successful Sync Time: 05.09.2009 20:06:21
    
    Source: Local CMOS Clock
    
    Poll Interval: 6 (64s)
    
    
    C:\Users\Administrator.MHG>w32tm /config /manualpeerlist:"ntp.uio.no;timekeeper.
    uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn
    cfromflags:manual /reliable:yes /update
    
    The command completed successfully.
    
    C:\Users\Administrator.MHG>w32tm /query /status
    
    Leap Indicator: 0(no warning)
    
    Stratum: 1 (primary reference - syncd by radio clock)
    
    Precision: -6 (15.625ms per tick)
    
    Root Delay: 0.0000000s
    
    Root Dispersion: 10.0000000s
    
    ReferenceId: 0x4C4F434C (source name:  "LOCL")
    
    Last Successful Sync Time: 05.09.2009 20:06:21
    
    Source: Local CMOS Clock
    
    Poll Interval: 6 (64s)
    
    