Raid 1 disk failure recovery on Dell Poweredge 2850 - how to repair?

16,440

Logical drive 0 (RAID 1) has a failed hard drive or has not been rebuilt. Drive 4 appears to be the mirror of drive 1. Be very careful here and make sure you have a backup of all your data before proceeding. I'd consider placing drive 0 in slot 4 and see if it rebuilds. But, I can't verify from the screen shots which physical drives belong to which logical drives and what sizes they are. At this point be very sure of what you're doing.

EDIT: Looking at the screen shots again it appears that LD0 is using slots 1 and 4 and LD1 is using slots 2 and 3. Confirm the hard drive sizes in the slots and proceed accordingly. (Have a backup!)

Share:
16,440

Related videos on Youtube

Saul
Author by

Saul

Updated on September 18, 2022

Comments

  • Saul
    Saul almost 2 years

    Ive just spotted an amber disk error message on my 2850, E0D76 BP drive 4 fail. Drives are ULTRA 320 SCSI. Its been a while since this server was set up so I cannot be abolutely sure my memory is accurate but I think it was

    Drive 0 73GB
    Drive 1 73GB paired as RAID 1

    Drive 2 146GB
    Drive 3 146GB paired as RAID 1

    Drive 4 146GB as hot swap

    (I had a dodgy 146gb drive that was giving me flashing amber as a predicted fail but I thought better than nothing to leave it as the hot swap in drive 4)

    I think I had the config as

       Raid Ch- 0
    ID
    
    0 ONLIN A00-00
    1 ONLIN A00-01
    2 ONLIN A01-00
    3 ONLIN A01-01
    4 HOTSP
    

    So on checking the config i now see

    enter image description here

    enter image description here

    Seeing drive 4 as failed I removed it , and re-sited it and rebooted but still failed. So I rebooted without it in which gave a POST warning but corrected the LED error from amber to blue.

    My question is, can someone with a clue help me figure what has happened, and how can I recover it?

    [EDIT] Whats the best way to monitor hardware RAID failure, its PERC 4e/Di controller, OS is Windows Web Server 2008 R2. Can the state of the RAID array be monitored from within windows? Is there some error thrown in the event log that I can hook a warning event on to?

  • Saul
    Saul almost 13 years
    I've got my data backed up already but I would still like to get this right :) If I put a new 73GB drive into drive 0 , it doesn't look like it would simply rebuild? presume I would have to config it as part of A00, then it would ? What I don't get is how the config seems to have migrated from what I remember to what I see now, unless my memory is worse than I thought
  • murisonc
    murisonc almost 13 years
    It really appears that LD0 is using slot 1 and 4. So I'd put the new 73GB drive into slot 4 and it should rebuild. Memory is the first thing to go with age :)
  • Saul
    Saul almost 13 years
    Ive got one on order murisonc and Ill update when I have put in the replacement
  • murisonc
    murisonc almost 13 years
    It should rebuild on it's own but I'd verify it's working. There is a tool called Dell OpenManage Server Administrator (free) that can be installed to manage the RAID without rebooting the server.